The HeatWave SuperQuiet® SQ145 comes equipped with all standard features. The Patented ThermoLink® Titanium Heat Exchanger at its core makes this unit a power-house that’s built to last.
The only heat pump that allows you to maximize the potential savings of a variable speed pump is an AquaCal®, which utilizes our patented ThermoLink® Heat Exchanger technology with its unique flow characteristics.
• Patented hydraulic design adds only 2 PSI at 45 gpm, increasing compatibility with two-speed & variable speed pumps
• Saves money when using a variable speed pump by reducing the RPM needed to achieve the same flow rate
• Save money in a single speed pump application by reducing the run time needed to achieve the same turnover rate of the pool
Corrosion Proof Cabinet
• Louvered side panels protect evaporator coil while ensuring efficient air flow
• Rust and fade proof
• Impact resistant
• Built-in drain pan provides condensate management
AquaTop
• Unique Air Flow Vectoring Top ensures optimal air flow for maximum efficiency
• World’s ONLY integrated top that protects internal components and prevents debris like leaves and other vegetation from getting inside the heat pump, rotting and becoming acidic
• Protection provided by the AquaTop allows for an extended 10 year warranty on the evaporator coil
Microprocessor Controlled with Digital Display
• Weather protected control with full text display provides easy-to-read menu options and unit status
• Ability to connect to most external controllers for heating and cooling mode
• Hybrid functionality can initiate a gas heater when an extra boost of heat is needed
60 Hz | SQ145 |
---|---|
BTUs (water temp/ambient air/relative humidity) |
|
80/80/80 | 121,000 |
80/80/63 | 115,000 |
80/50/63 | 75,000 |
Coefficient of Performance (water temp/ambient air/relative humidity) |
|
80/80/80 | 7.1 |
80/80/63 | 6.8 |
80/50/63 | 4.2 |
Refrigerant | R410A |
Electrical | |
Heat or Heat & Cool | H |
kW Input | 5.1 |
Voltage/Hz/Phase A – 208-230/60/1 B – 200-230/60/3 E – 380-415/60/3 G – 460/60/3 |
A, B & G |
Minimum/Maximum Fuse Size | A – 60 B – 50 G – 20 |
Minimum Circuit Ampacity | A – 42.1 B – 31.0 G – 14.2 |
Water Flow *A Heater Bypass Kit is required when flow rates exceed the maximum |
|
Minimum/Maximum (gpm) | 30/70 |
Physical | |
Weight (lbs) | 305 |
Length x Width x Height (in) | 34″ x 34″ x 44″ |
Shipping | |
Weight (lbs) | 345 |
Length x Width x Height (in) | 37″ x 36″ x 51″ |
Product Brochure
Installation Manual
Operations Manual